您的当前位置:首页正文

电路电子常用资料全模板

来源:意榕旅游网

Q/GZSHDZ 001-

术资

广州思弘电子科技

4

目录

一、电缆型号、载流量及估算口诀、 常见元器件标识、 导线线号标

··1

1.1

·····································

··················1

1.2

·····································

··········2

1.3

·····································

············3

1.4

线

线

·····································

··············3

·······························

·····4

2.1

·····································

···········4

2.1.1

··········································

······················4


2.1.2

······························································4

2.1.3

······················································4
2.1.4阀门································································5

2.1.5

··················································7

2.1.6

····························································7

2.1.7

····························································8

2.1.8

····························································9

2.1.9

····························································9

2.2

·······················································10

2.3

A~Z


··························11

2.4

·································12

2.5

···································

14

三、常见设备、

材料及常见设备、

材料规格参

···················20

3.1

·····································

······20

3.2

·····································

······20

·······························

···················21

一、电缆型号、 载流量及估算口诀、 导线线号标识

1.1电缆型号

电力电缆型号各部分代号及其含义

1.电缆种类:R 连接用软电缆,软结构;K 控制电缆;P 信号电缆。

2.绝缘种类:V 聚氯乙稀;X 橡胶;Y——实心聚烯烃(聚乙烯)绝缘(YF泡沫聚烯烃绝缘 YP泡沫/实心皮聚烯烃绝缘 YJ交联聚乙烯);Z 代表纸。

3.导体材料:L ; T(省略)铜。

4.内护层: V 聚氯乙稀护套;Y 聚乙烯护套;L 铝护套;Q 铅护套;H 橡胶护套;F 氯丁橡胶护套;A——涂塑铝带粘接屏蔽聚乙烯护套 S——,钢双层金属带屏蔽聚乙烯护套
5.特征: D 不滴流;F 分相;CY 充油;P 贫油干绝缘;P 屏蔽;Z 直流。

6控制层: 0 ;2 钢带;3 细钢丝;4 粗钢丝;5 钢带皱纹纵包7.外被层: 0 ;1 纤维外被;2 聚氯乙稀护套;3 聚乙烯护套。

8.类型:B-平型(扁形) S-双绞型。

9.阻燃电缆在代号前加ZR;耐火电缆在代号前加NH

示例:KVV22 聚氯乙烯绝缘聚氯乙烯护套钢带铠装控制电缆 ZR-KYJVP 交联聚氯乙烯绝缘铜丝屏蔽阻燃控制电缆

1.2常见电缆载流量对照表及估算口诀

常见电缆载流量对照表及估算口诀

序号

1

2

3

4

5

6

7

8

9

10

11

12

13

14

15

铝电缆截面mm²

1

1.5

2.5

4

6

10

16

25

35

50

70

95

120

150

18


倍数

9

9

9

8

7

6

5

4

3.5

3

3

2.5

2.5

2

0
2


9

13.5

22.5

32

42

60

80

100

122.5

150

210

237.5

300

300

36



25

倍数

8.1

8.1

8.1

7.2

6.3

5.4

4.5

3.6

3.15

2.7

2.7

2.25

2.25

1.8

0
1.8

安全电流(A

8.1

12.15

20.25

28.8

37.8

54

72

90

110.25

135

189

213.75

270

270

324

穿

穿2根倍数

7.2

7.2

7.2

6.4

5.6

4.8

4

3.2

2.8

2.4

2.4

2

2

1.6

1.6

穿3根倍数

6.3

6.3

6.3

5.6

4.9

4.2

3.5

2.8

2.45

2.1

2.1

1.75

1.75

1.4

1.4

穿4根倍数

5.4

5.4

5.4

4.8

4.2

3.6

3

2.4

2.1

1.8

1.8

1.5

1.5

1.2

1.2

穿2根电流

7.2

10.8

18

25.6

33.6

48

64

80

98

120

168

190

240

240

288

穿3根电流

6.3

9.45

15.75

22.4

29.4

42

56

70

85.75

105

147

166.25

210

210

252

穿4根电流

5.4

8.1

13.5

19.2

25.2

36

48

60

73.5

90

126

142.5

180

180

216


线

截面当量

1

1

1.5

2.5

4

6

10

16

25

35

50

70

95

120

150



二点五下乘以九, 往上减一顺号走

2.5mm²以下电缆9,4mm²电缆8,6mm²电缆7,10mm²电缆6,16mm²电缆5,25mm²电缆4

三十五乘三点五, 双双成组减点五

35mm²电缆3.5, 5070mm²电缆3, 95120电缆2.5, 150180电缆2

条件有变加折算, 高温九折铜升级

温度大于25℃, 倍数打九折, 铜线降一级, 25mm²铝电缆相当于16mm²铜电缆

穿管根数二三四, 八七六折满截流

一根管穿二根电缆倍数打8, 穿三根电缆倍数打7, 穿四根电缆倍数打6



10下五, 100上二

10mm²以下电缆按5倍电流算, 100mm²以上电缆按2倍电流算

2535, 四、 三界

1625mm²电缆按4倍电流算, 3550mm²电缆按3倍电流算

7095, 两倍半

7095mm²电缆按2.5倍电流算

穿管、 温度, 八、 九折

穿管打8, 高温打9

裸线加二分之一

裸线截流量加一倍, 即原绝缘线电流容量1.5

铜线升级算

铜线截面排列次序提升一级

说明: 1.三相四线制中零线截面通常选为相线截面1/2左右。
2.在单相线路中, 零线和相线截面相同。


1.3 常见元器件标识(未完待续)
以下为制冷行业常见元器件标识,其它电路元器件标识可参考本资料P13

BP压力变送器;BT 温度变送器;BTM 风机
EH发烧器件;EHD; EL 照明灯;EV 空气调整器;E 蒸发器;EC 冷凝器
FA空气开关;FU 保险;FR(马达)过载保护
HA声响指示器;HL 指示灯;
K继电器;KA 电流继电器;KG 固态继电器;KM 交流接触器;KV 电压继电器;KT 时间继电器M电机;MC 压缩机;MCF 冷凝器风机;MF 风机;
PA电流表PV电压表PJ电度表
QA自动开关;QF 低压断路器;QK 刀开关;QM 电动机保护开关;QS 隔离开关
RT热电阻;RP 电位器
SA选择开关;SB 按扭开关;SV 液压阀、膨胀阀
T电力变压器;TB 开关电源;TA 电流互感器;TV 电压互感器
X接线端子排组;XS 插座;XP 插头;XT 端子排;XE 测试端子
Y电磁阀

1.4 线号
标准上导线两端标识应一致,通常采取数字或数字和文字组合
交流系统电源接线L1L2L3N(或ABCN) 有相序要求如电机接线UVWN。接大地保护线为PE

直流系统电源线:L+L-,L 为电压值,中间线M、电器箱内部保护接地GND
1.断路器输入:L1L2L3,零线N,输出:101201301,零线01
2.空气开关输入:101201301输出:102202302···一组,104204304···一组,以这类推。零线01

3.交流接触器输入:同接线另一端(如空气开关)输出:103203303·· · 一组,105,205,305···一组,以这类推。交流接触器控制信号线和导线另一端一致

4.继电器:输出端线号标其功效,如控制加热丝EH+、照明灯EL之类。其它线号和线另一端一致。

没有具体功效定义标401~499,601~699
5.开关电源、变压器、 互感器输入端同另一端。 开关电源输出xxVDC+801803 805···,xxVDC-800802 804···,变压器,互感器输出501502 , 503 504, ··

6.PLC,其它控制模块,集成块在配电板用其型号做标识。接线标识通常参考其上标识,I01,D02, +24V, GND, PID-T
7.变频器接线标识为:控制信号线号标变频器上接线端子英文名称前3个字母,输入和另一头接触器一致,输出UVW

二、图形符号及电气文字代号
2.1设备图形符号表示
2.1.1管道

2.1.2管接头

2.1.3管路弯头及三通

2.1.4 阀门

2.1.5 控制元件和测量用表

2.1.6 管路附件

2.1.7 动力机械

2.1.8 辅助设备

2.1.9 制冷机组

2.2 介质代号

2.3电气技术中项目种类字母代码表

2.4 常见电气设备文字符号新旧对照表

2.5常见电器图符号及和国外对比

三、常见设备、材料及常见设备、材料规格参数

1、常见设备

变压器、互感器、 调压器、 感应移相器、 电抗器、 高压断路器、高压熔断器、 稳压器、

电源调整器、高压隔离开关、 装置或空气开关、 电容器、 蓄电池、磁力开启器及其按钮、 电加

热元件、交流报警器、 成套配电箱、 盘、 柜屏及其母线和支持瓶探测器、模块、 手动报警按钮、

消火栓报警按钮、电话、 消防系统接线箱、 反复显示器、 报警装置、入侵探测器、 入侵报警控

制器、报警设备传输设备、 出入口控制设备、 安全检验设备、电视监控设备、 终端显示设备,

发器,冷凝器,压缩机等均为设备。

2、常见材料

多种电缆、电线、 母线、 管材、 型钢、 桥架、 灯具及多种支架、P型开关、保险器、 绝缘子、

金具、线夹、 开关、 插座、 按钮、 接线箱、 接线盒、 电铃、风扇、 电线杆、 铁塔,加热器,

槽钢,角钢,角铝,线槽等均为材料。

3、常见设备、 材料规格,参数

EXCEL表格《物料.xls

四、相关思弘

广州思弘电子科技关键从事可靠性环境试验设备研究、开发、 制造、 销售及售后服务。 产

品关键应用于气候环境仿真相关试验,有高温试验箱、高低温试验箱、 高低温湿热试验箱,高温

恒湿试验箱、高低温冲击试验箱、 高变温速率环境应力筛选试验设备、温度/高度试验箱、温度/

高度/湿度试验箱、温度/湿度/振动综合环境试验箱及和之相对应步入式试验室等数十个品种;也可

依据用户指定要求设计、制造多种非标试验设备,最大程度地满足用户需求和期望。上述产品广

泛应用于大专院校、研究所、 电子机械、 电工、 仪器仪表、 航空、 航天、军事、 造船、 兵器、

汽车、轻工、 化工、 医疗等领域。

地址:广州市天河区元岗路北街11号之101

口号:

显示全文