10KV高压电动机技术要求
甲 方:大连福佳·大化石油化工有限公司
乙 方:
日 期:
Page 2 of 5
目 录
1 2
总则·························································································································· 3 技术要求··················································································································· 3 2.1 使用环境条件 ································································································· 3 2.2 基本参数要求····································································································· 3
2.3 其他要求············································································································ 4 3 检查和试验··················································································································· 4
3.1 试验··················································································································· 4
3.2 厂家通知 ·········································································································· 4 4. 制造标准··················································································································· 4
2
Page 3 of 5
1
总则
乙方负责甲方芳烃联合装置10KV高压电动机的材料采购、制造、检验、试验、预组装、运输。乙方应严格按照设计图纸进行制造和安装,并应满足本技术要求的规定。本技术要求正本一式二份,甲方、乙方各执一份。 2
技术要求
2.1 使用环境条件
(1) 安装地点:户外
(2) 海拔高度:1000m以下 (3) 环境气温:-30℃~+40℃ (4) 最大日温差:35℃
(5) 最大相对湿度:95%(25℃)
(6) 耐受地震能力:耐受烈度:8度,水平加速度0.15g,按标准试验,安全系数1.67。 (7) 污秽等级:2000版Ⅲ级。 2.2 基本参数要求
序号 01 02 03 04 05 06 07 08 09 10 11 12 13 14 15 16 17 18 19 20 21 22
名 称 型号 额定功率 额定电压 相数及频率 堵转时间 启动电流倍数 效率 功率因数 绝缘等级 冷却方式 安装方式 电动机振速 旋转方向 防爆级别 防护等级 噪音 工作制式 防腐等级 定子远程温度检测RTD 10000V 基 本 要 求 3/50 TE≦10秒 ≧7倍Ie ≥92% 2或4极电动机≦0.85 F级绝缘,B级温升考核 IC611 IMB3、IMB5 ≧2.8mm/s 根据泵的要求并做标记 DⅡCT4或eⅡT3 主体IP54、接线箱IP55 额定功率≤500KW的电动机噪音按85dB考核,额定功率>500KW的电动机噪音按95dB考核 S1 WF1 有(PT100)、设独立接线盒 有(PT100)、滑动轴承需远传,设独立接线盒 中心高≤315MM的安在顶部,接线盒在右侧(从轴伸端看) 75KW及以上的滚动轴承电机 3
轴承温度就地显示/远传(安装在电动机左右侧) 接线盒安装部位 注油孔 Page 4 of 5
23 24 25 26 2.3 其他要求 滑动轴承润滑方式 磁力中心线 滚动轴承 空间加热器 尽可能采用自润滑(自带甩油环式) 采用滑动轴承的电机均要有磁力中心线标识 采用进口SKF(瑞士) 设独立接线盒 2.3.1 电动机的性能符合GB755(旋转电动机技术要求)的规定。
2.3.2 电动机的端电压在下降到额定电压的90%时,电动机可以满载直接启动,并可以在满负荷下连续运行。
2.3.2当电源电压变化不超过±10%时,电动机的输出功率应连续保持额定,此时温升符合B级要求;
2.3.3当电源频率变化不超过±5%时,电动机的输出功率应保持保持额定,此时温升符合B级要求;
2.3.4当电源频率变化在-4~+2%,同时电源电压变化不超过±5%时,或出现极限偏差时,电动机的输出功率应保持额定,此时温升符合B级要求; 2.3.5当电源电压变化不超过±10%,同时频率变化不超过±2%时,或电源电压在80%时,允许直接启动;
2.3.6当频率为50HZ,电源电压在75%时,电动机应连续运行2分钟,而无有害过热(即电动机最高表面温度不超过T3所允许的温度200℃); 2.3.7电动机在1.2倍超速运行2分钟不应有变形; 2.3.9电动机应满足沿海气候的要求;
2.3.10接线盒应带符合防爆要求的密封接头,电动机接线盒应满足非铠装电缆的要求,配金属螺纹口,带GLAND头;
2.3.11 电动机允许满载全压直接启动,正常启动允许冷态连续启动2次,热态连续启动1次;
3 检查和试验
3.1 试验
电动机生产厂按照国家标准和福佳·大化石油化工有限公司的要求对电机进行试验,试验不少于以下内容:
1) 定子线圈电阻测试 2) 空载和堵转特性试验 3) 满载性能试验
4) 绝缘电阻和交流耐压试验 5) 温升试验 6) 转子动平衡试验 7) 振动试验 8) 噪声试验
3.2 厂家通知
电动机出厂试验前一周电动机生产厂应以书面形式通知大连福佳·大化石油化工有限公司 4. 制造标准
设备制造及安装符合(不限于)如下标准 : GB/2326-2000 电能质量电压波动和闪变 GB/755-2000 旋转电机基本技术要求
GB/50060-92 3~110kV 高压配电装置设计规范
4
Page 5 of 5
SH/T3131-2002石油化工电气设备抗震设计规范 SH/T3072-1995石油化工企业电气图图形和文字符号 SH/3038-2000石油化工企业生产装置电力设计技术规范 GB/50055-93通用用电设备配电设计规范
5